Air Shower

ROYAL AIRCON (AS) is designed to supply Class 100 HEPA filtered air at high velocity to remove particulate matter from the person before entering into the Clean Room.

Air Shower works as partial clean equipment installed at the partition between the clean room and non-clean rooms to shower the personnel before entering the clean area. This unit helps to remove dust effectively and maintains the normal working status.

Operating Conditions

Air cleanliness: ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocities: 18 – 20 mps
Light Intensity: Minimum

  Standard Models   Work Area Dimension (L × W × H)
  AS – 001   700 X 850 X 2000 MM
  AS – 002   700 X 1200 X 2000 MM

General Specifications

  • Two Stage filtration
  • DOP Test Port
  • 5/15 Amp Switch Socket for external equipment Control Systems Timer for setting
  • Air Shower operation time (settable for 30 seconds to 5 minutes)
  • Emergency STOP